Regeneration System
Regeneration is the restoration of used oil to virgin oil specifications, or even higher. Fowler Westrup regeneration systems have a reactivation feature which enables special environmental friendly media to be reused several hundred times before recharging the system with new media. Our optimized regeneration system uses dual banks of regeneration columns which provide for continuous operation of the system by regenerating oil in one bank while reactivating the media in the other bank.
Regeneration is the greenest technology offered today and It is a revolution in the oil filtration industry where the resultant savings for the user in terms of investment and oil is enormous.
Fowler Westrup carries out a through study of the client's requirement, recommends solutions, creates customized designs, implements the solution and even trains personnel to operate and maintain the systems. Most importantly, we support them fully incorporating our system seamlessly into customer's existing infrastructure.
Regeneration Cycle
- Transformer or Oil tank
- Heat and Pre-filter
- Adsorbent media in columns
- Fine filtration
- Vacuum degasification and dehydration
- After filter
Applications
- Transformer Oil
- Lubricating Oil
- Hydraulic Oil
- Engine Oil
- Cable Oil
Features
- Advanced design with superior quality
- Stationary & mobile configurations
- Reusable Media
- Rejuvenates the life of oil and makes it an asset
- Manual /fully automatic with SCADA system
- Fully customizable with flow rateranging from 500 LPH to 6000 LPH & above
Benefits
- Life extension of a limited resource
- Economically advantageous
- Extended life of expensive capital equipment
- Minimal running cost
- Huge savings due to media re-activation
- Fully customizable
- Futuristic technology for online / offline applications
Turnkey Solutions
- Installation
- Commissioning
- Customer service
- Spares
- Service and maintenance schemes
- Technical support network
Parameter
Unit
Used Oil
After Regeneration
Appearance
Cloudy, brown
Sparkling, clear & transparent
Breakdown Voltage
kV
15
70
Interfacial Tension @27°c
N/m
0.02
0.04
Neutralisation value
mg KOH/g oil
0.5
0.03
Resistivity @27°c
ohm-cm
1.0x10¹²
1500x10¹²
Resistivity @90°c
ohm-cm
0.1x10¹²
35X10¹²
Tan delta @90°c
1.0
0.002